Analysis of Dongguan Chengbang precision electromechanical Co., Ltd.: what are the hazards of three-phase imbalance

From:Chengbang Shengbang precision machinery (Jiangsu) Co., Ltd  Time:2019-9-29 8:59:41  Hits:



1Main hazards caused by unbalanced three-phase voltage or current


1、When the rotating motor operates in an asymmetric state, it will cause additional loss and heat to the rotor, which will cause the whole or local temperature rise of the motor. In addition, the additional torque generated by the reverse magnetic field will cause the motor to vibrate. For the generator, a series of higher harmonics will be formed in the stator.  


2、Many kinds of protection with negative sequence component as starting element are misoperated, which directly threatens the operation of power grid. 


3、Unbalanced voltage causes non characteristic harmonics in silicon rectifier。  


4、For generators and transformers, when the three-phase load is unbalanced, if the maximum phase current is controlled as the rated value, the other two phases cannot be fully loaded, so the utilization rate of the equipment decreases. Otherwise, if the rated capacity is to be maintained, the overload of one phase with large load will be caused, and the unbalanced magnetic circuit will cause waveform distortion, and the additional loss of the equipment will be increased。


2Solutions to three-phase voltage imbalance caused by asymmetric load


1、In order to reduce the problem of unbalanced degree caused by the centralized connection, the asymmetrical load is connected to different power supply points。  


2、Use the method of cross exchange to distribute the unsymmetrical load to each phase reasonably and balance it as much as possible。 


3、Increase the short-circuit capacity of the load access point, such as changing the network or improving the power supply voltage level to improve the system's ability to withstand unbalanced load。





Website:


Prev:Dongguan city state precision mechanical and Electrical Co., Ltd. analysis: motor used frequency converter leakage is what?

Next:Dongguan city state precision mechanical and Electrical Co., Ltd. analysis: why does China's motor choose 50Hz alternating current?

Chengbang Shengbang precision machinery (Jiangsu) Co., Ltd
Address:7 Dongbao Road, Niutang Town, Wujin District, Changzhou City
Tel:0519-88998190
Fax:0519-88996290
Hu Qian bin:13018665114
Email:596516651@qq.com
Dongguan Chengbang precision electromechanical Co., Ltd
Address:7 Keji Avenue, Houjie Town, Dongguan City
Tel:0769-85343611
Fax:0769-85343612
Yan Jin Hua:13450623531
Email:122086354@qq.com
Copyright:Chengbang Shengbang precision machinery (Jiangsu) Co., Ltd    Supporter:yunjisuan    Record number:Su ICP B No. 19056343